Physiochemical Test

 
Physical Chemical General
Concentration/Relative density&gravity
Suspended Particles Concentration Measurement
Professional Density/Gravity
Professional Viscosity
Liquid/liquid, Liquid/solids Interface Level Detection

Download Acrobat Reader

Physical Chemical General 

AV1720 Physicochemical Analyzer      [Introduction] [Datasheet ]   [User Application Data Form]

Ultra sonic velocity difference test, to monitor dynamic changing of liquid concentration, polymerization, gravity and density, elastic module, solid mixed ratio, materials strength etc.

PC1720 Physiochemical Analyzer          [Introduction] [Datasheet ]   [User Application Data Form]

H-BD5 PC1720 Physiochemical Analyzer

Ultrasound velocity Method.

To test the concentration of liquids, polymerizing conversion, specific weight/density, elasto-viscosity behavior, etc.

PC1730 Physichem Analyzer           [Introduction] [Datasheet]  [User Application Data Form]

HBD5 PC1730USa Physiochemical Analyzer

Ultrasound Attenuation Method

This instruments is designed to tune the wavelength from 20kHz to 100MHz.Overlaying the ultrasound and wide electromagnetic segment. Employing attenuation test electronics.

Specially used to analyze the particles suspended system, as while as concentration application. and even hoped to get the composition  analysis results for some samples.

 

Concentration/Relative Density&Gravity Measurement

CCT 1720 AV  Concentration Transducer    [Introduction] [Datasheet ]   [User Application Data Form]

Supersonic velocity transmission difference method. Suitable to monitoring the mixing ration of 2 part materials, that have different acoustic velocity. Range:0.1-100%; Accuracy:0.1% FS; Applicable to mixed gases, liquids, and some mixed or melt solids.

Hand held BD5EMC1204 Concentration Teller   [Introduction]  [Datasheet]   [User Application Data Form]

Smart Test, read concentration just instant

RF Attenuation Method

Magnetic-electric method, to measure the concentration of mixtures from polarized and impolarized, organic and inorganic compounds through being dissolved, suspended, mixed, whatever. Having the same concept to monitor relative density and gravity.

Range:100ppm-Saturated(TDS) or 100% (Mix ratio);

Repeatability :+/-0.01 to 0.1% +/-0.5%FS while polar part <2%; +/-1.5% Max difference).

 

 

EMC 1130 HFC Concentration Transducer      [Introduction] [Datasheet ]  [User Application Data Form]

High frequency conductivity technology, to measure concentration continuously for salt, acid, and alkaline solutions over ppm.

  •  Range: 0/100ppm-Saturated(~50%TDS);
  • Repeatability:<+/-0.1%FS
  •  Temperature: -40 to 120, Max to 400
  • Pressure: 0-1.6Mpa (Max: 4.0 Mpa)

EMC1204 Concentration Transducer        [Introduction] [Datasheet ]  [User Application Data Form]

Magnetic-electric method, to measure the concentration of mixtures from polar and neutral, organic and inorganic compounds through being dissolved, suspended, mixed, whatever. Having the same concept to monitor relative density and gravity.

  • Range:100ppm-Saturated(TDS) or 100% (Mix ratio);
  • Repeatability :+/-0.01 to 0.1%+/-0.5%FS while polar part <2%; +/-1.5% Max difference
  • Temperature: -40 to 120, Max to 400
  • Pressure: 0-1.6Mpa (Max: 4.0 Mpa)

CCT 1511MWA Concentration Transducer   [Introduction] [Datasheet ]   [User Application Data Form]

Microwave transmission attenuation method. to measure the concentration of mixtures from polar and neutral, organic and inorganic compounds through being dissolved, suspended, mixed, whatever. Having the same concept to monitor relative density and gravity. Range:0.1-Saturated(TDS) or 100% (Mix ratio); Repeatability accuracy:+/-1%FS+/-2% while polar part <2%; +/-2.5% Max difference. Advantageous to EMC1204 while SCT> 12ms/cm; Inferior to EMC1126 while SCT more higher

CCT 2222 TCD Gas Concentration Transducer   [Introduction] [Datasheet ]   [User Application Data Form]

TCD method. Self heating thermistor design, economic system. Range:100ppm-100%; Response time:<45s(95%); Repeatability accuracy:<+/-5%FS

DST 6330 -ray Density Meter   [Introduction ] [Datasheet] [User Application Data Form]

Dispersing effect, to measure density for liquid, sludge, (slug,) slurry, slush, solids. Used for special fields where other density technology is not easy to be installed, such as sealed container, corrosive or caustic liquid pot, high temperature and or explosive field. And also reducing the influence of bulbs encapsulated, which strongly influence other density test technology. Range: no limits; Repeatability accuracy:+/-2.5%FS; Rapid response time: 100ms

 

Suspended Particles Concentration Measurement

SST 1739 USDA Suspended Solids Intelligent Analyzer   [Introduction] [Datasheet ]   [User Application Data Form]

on-line measurement
T001-BD5xMD SST1739 USa Suspended Solids Transducer
SST1739 USDA use the dispersing attenuation of ultrasonic measure the concentration and average size of suspended solids. Specially in modulating supersonic dispersing technology, to analyze the size and it's distribution, as while to intelligently calculate the concentration of dispersed and/or suspended particles in the compounds, such as mud, sludge, slurries, gel etc. The best way to monitor process of coagulation, coacervation, agglutination, solidifying, condensing etc.
Concentration Range: 1% to 50%wt (might be higher in certain applications)
Accuracy: <5% typicalrelative to calibration samples
Particle Size Range: 10nm to 1000 um
Standard deviation of the geometric mean: <2.5
Sample Pressure: 10 Bar (PN10) 105 Bar
Sample Temperature: -40 to +70 , Max to 150
Response: 100ms
Serial communication: RS232/485, STIMcom/Modbus, IEEE1451.2 compatible
Signal output: 0/4–20 mA

 

SPM4210 Suspended Solids Teller   [Introduction] [Datasheet ]   [User Application Data Form]

HBD3 SPM4210 Suspended Solids Teller

Gas and Air Application

Light Dispersion Method

Range: 0-10,1000,10000 mg/m3;
Application for SPM in environ air; suspended solids in gas; particles in smoke

 

SPM4210 Suspended Solids in Air Transducer    [Introduction] [Datasheet ]   [User Application Data Form]

TBD5 SPM4210 Suspended Solids in Air Transducer

on-line measurement
Light Dispersion Method, Modern Data Process Analyzer
Range: 0-10,1000,10000 mg/m3;
Application for SPM in environ air test; suspended solids in gas; particles in smoke

 

Professional Density/Gravity

DST 1741 USrc  Density Transducer     [Introduction] [Datasheet ]   [User Application Data Form]

On-line installation Density Transducer

DS1741 is basically based on the sonic resistance principle, using plate vertical extraction wave. This is actually equal to the classic mechanic test of density. very reliable. Much definite than the sonic speed method.

  • Standard analog and RS232/485 data output, STIMcom/Modbus protocol supported network
  •  Accuracy: 0.025%FS @20°C
  •  Repeatability: 0.0001g/cc (0.1kg/m3)
  •  Range: 0.1-3 g/cc (0 - 3000kg/m3)
  • Sample Temperature: -50 to 400 °C
  • Sample Pressure: 0-4.0Mpa (Max:20.0 Mpa)
  • Analog output: 0/4-20mA
  • RS232/485: STIMcom/Modbus (Modicon)
  • Package: IP66
  • Safety: EEx d IIc T4  CSA Class 1, Division 1, Group C (pending)
  • Supply: 9 to 24Vdc, 100mA

Hand held Density Teller     [Introduction]   [Datasheet ]   [User Application Data Form]

Professional Smart test Densitometer / Hydrometer

DS1741 is basically based on the sonic resistance principle, using plate vertical extraction wave. This is actually equal to the classic mechanic test of density. very reliable. Much definite than the sonic speed method.

Accuracy: 0.0005g/L
Range: 0.3-3 g/L
Sample Temperature: -30 to 100 °C

 

 

 

 

 

 

 

DST 6330g -ray Density Meter   [Introduction ] [Datasheet] [User Application Data Form]

Dispersing effect, to measure density for liquid, sludge, (slug,) slurry, slush, solids. Used for special fields where other density technology is not easy to be installed, such as sealed container, corrosive or caustic liquid pot, high temperature and or explosive field. And also reducing the influence of bulbs encapsulated, which strongly influence other density test technology. Range: no limits; Repeatability accuracy:+/-2.5%FS; Rapid response time: 100ms

DST 1512 MWPD Densitometer   [Introduction] [Datasheet ]   [User Application Data Form]

The density meter uses microwave phase difference method to determine concentrations of solids in a fluid flowing in pipes. Using this method the LQ167C can perform a stable measurement resistant to the effects of contaminants or entrapped air in the fluid. The density meter has no moving parts such as those used for cleaning, sampling or defoaming purposes and this allows a continuous on-line operation. Range:0-~50%(TDS); Repeatability accuracy:+/-2%FS+/-4%FS,while TDS<2%

 

Viscosity Measurement

VST1742 UShr Viscosity Transducer              [Introduction] [Datasheet ]   [User Application Data Form]

n VS1742 UShr Viscosity Transducer  

On-line installation, Professional Viscosity Measurement

Ultra sonic vibration method to measure (h r )1/2, then calculate the viscosity h . No moving parts and rigid design to suit any industrial condition. Applicable to all Newtonian fluids, and also non Newtonian fluids with inferior accuracy. No maintenance, rugged design. With advanced electronics.

  • Range: 0-109cP;
  • Accuracy:± 1% of reading;
  • Repeatability:± 0.3% R;
  • Sample temperature: 100.200.300. up to 400 °C
  • 0-4.0Mpa (Max:20.0 Mpa)
Hand held -VS1742 Viscometer             [Introduction] [Datasheet ]   [User Application Data Form]
HBD5VS1742 Portable Viscometer:

Ultra sonic vibration method to measure (h r ), then calculate the viscosity

Range: 0-10,000cP;
Accuracy: ± 1%R;
Repeatability:± 0.3% R;
Sample temperature: 100 ° C
 

 

Liquid/liquid, Liquid/solids Interface Level Detection

   
 
BIG DIPPER TECHNOCHEM INSTITUTE
Call: (86) 10-8264.0225; 8264.0226  Fax: 86-10-8264.0221 ;
P.o.Box: 603 BDTI
Beijing, China 100190
http://www.BD-research.com/
email: [email protected]; [email protected];
 

http://www.BD-research.com/Products/PhysioChem/physiochemListE.htm